It may have double interior pair separators and or a rigid jacket with a gear shaped interior wall to create interior air space and decrease.
Cat 6 cable outer diameter.
To find out how many cables you can run in a given conduit size enter your belden cable part number or enter the diameter of your cable.
Cat 6 supports 10 gigabit ethernet only up to 164 feet of cable length.
Next select the type of conduit you are specifying.
The wire pairs must not be untwisted and the outer jacket must not be stripped back more than 13 mm 0 51 in.
The category 6 augmented cable standard or cat 6a was created to further improve the performance of cat 6 ethernet cables using cat 6a enables 10 gigabit ethernet data rates over a single cable run up to 328 feet.
Every level exceeds tia 568 c 2 s performance and are produced with belden s superior quality.
Category 6 and 6a cable must be properly installed and terminated to meet specifications.
Velocity of propa gation 0 90 2 3 cm time delay 46 lbs 20 9 kg per 1000 ft 304 8 m shipping weight per standardcoverage length awg diameter stranding material nom.
The cat 6e 550mhz plenum rated cable now has a 0 200 inch od and the riser rated version has a 0 215 inch od.
Cat6a utp cable design differs among manufacturers.
Then under conduit size select the size of your conduit and hit calculate to determine the size of conduit you need in order to fit your chosen cable.
The outside diameter of cat6a f utp can be as large as 0 354 compared to 0 265 0 30 for cat6a f utp and 0 21 9 24 for cat6.
Dc resistance nominal individual cable outer diam.
Specifications utp cat 6 cable db 100 ft 30 48 m db 100 m.
Both cables are made with 23 awg solid bare copper conductors.
25 year warranty available with mac program 30 db minimum acr 100 mhz proven support for gigabit ethernet 1000base t ieee 802 3ab atm up to 155 mbps ieee 802 3af power over ethernet for voip 100 mbps fast ethernet 100base t ieee 802 3 ansi x3 263 fddi tp pmd ethernet 10base t ieee 802 3 4 16 mbps token ring ieee 802 5 t1 e1 xdsl isdn 550.
Dc resistance shield material nom.
Belden offers several category 6 performance levels including our 3600 series with premium performance offering significant headroom and our 2400 cat 6 enhanced system cable.
Jackets inner outer.
The bend radius should be larger than four times the outer diameter of the cable.
The cable must not be kinked or bent too tightly.
The plenum cmp rated category 6 cable now has an outside diameter of 0 190 inches and the riser cmr rated category 6 has a 0 200 inch od.